A dosimetric study of prostate brachytherapy using Monte Carlo simulations with a voxel phantom, measurements and a comparison with a treatment planning procedure

dc.TypeArticlept_BR
dc.contributor.authorRosa, Luiz Antonio Ribeiro da
dc.contributor.authorTeles, Pedro Peixoto
dc.contributor.authorZankl, Maria
dc.contributor.authorVaz, Pedro
dc.contributor.authorSoares, Alessandro Facure Neves de Salles
dc.contributor.authorPereira Júnior, Pedro Paulo
dc.contributor.authorSantos, Maíra Ribeiro dos
dc.contributor.authorBarros, Silvia
dc.contributor.authorCardoso, Simone Coutinho
dc.date.accessioned2023-01-24T17:52:26Z
dc.date.available2023-01-24T17:52:26Z
dc.date.issued2015-07
dc.description.abstractIn prostate brachytherapy treatments, there is an initial swelling of the prostate of the patient due to an oedema related to the insertion of the seeds. The variation of the prostate volume can lead to variations in the final prescribed dose in treatment planning procedures. As such, it is important to understand their influence for dose optimisation purposes. This work reports on a dosimetric study of the swelling of the prostate in prostate brachytherapy using Monte Carlo simulations. Dosimetric measurements performed on a physical anthropomorphic tissue-equivalent prostate phantom and thermoluminescent dosimeters (TLDs) were used to validate the MC model. Finally the MC model was also used to simulate prostate swelling in a real treatment planning procedure. The obtained results indicate that the parameters mentioned above represent a source of uncertainty in dose assessment in prostate brachytherapy, and can be detrimental to a correct dose evaluation in treatment plannings, and that these parameters can be accurately determined by means of MC simulations with a voxel phantom.pt_BR
dc.identifier.issn1742-3406
dc.identifier.urihttps://ninho.inca.gov.br/jspui/handle/123456789/12439
dc.publisherRadiation Protection Dosimetry (2015), Vol. 165, No. 1–4, pp. 482–487pt_BR
dc.subjectMétodo de Monte Carlopt_BR
dc.subjectMonte Carlo Methodpt_BR
dc.subjectBraquiterapiapt_BR
dc.subjectBrachytherapypt_BR
dc.subjectPróstatapt_BR
dc.subjectProstatept_BR
dc.subjectNeoplasias da Próstatapt_BR
dc.subjectProstatic Neoplasmspt_BR
dc.subjectSoftwarept_BR
dc.subjectDosimetriapt_BR
dc.subjectDosimetrypt_BR
dc.subjectTerapêuticapt_BR
dc.subjectTherapeuticspt_BR
dc.subjectPlanejamentopt_BR
dc.subjectPlanningpt_BR
dc.subjectMétodospt_BR
dc.subjectMethodspt_BR
dc.titleA dosimetric study of prostate brachytherapy using Monte Carlo simulations with a voxel phantom, measurements and a comparison with a treatment planning procedurept_BR

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A dosimetric study of prostate brachytherapy using Monte Carlo simulations with a voxel phantom....pdf
Size:
240.69 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.6 KB
Format:
Item-specific license agreed upon to submission
Description: