Radioterapia lattice: um estudo comparativo de viabilidade da técnica IMRT com a VMAT
| dc.Type | Article | pt_BR |
| dc.contributor.author | Gomes, Jheferson Salvador da Silva | |
| dc.contributor.author | Xavier Filho, Joel Marques | |
| dc.contributor.author | Fontana, Julia Martini | |
| dc.contributor.author | Santos, Maíra Ribeiro dos | |
| dc.contributor.author | Botelho, Marina de Arruda | |
| dc.date.accessioned | 2024-04-08T16:05:21Z | |
| dc.date.available | 2024-04-08T16:05:21Z | |
| dc.date.issued | 2024 | |
| dc.degree.department | COENS | pt_BR |
| dc.degree.grantor | INCA | pt_BR |
| dc.degree.local | Rio de Janeiro | pt_BR |
| dc.degree.program | Radioterapia | pt_BR |
| dc.description | 7 p.: il. color. | pt_BR |
| dc.description.abstract | O estudo comparativo incluiu dez casos de neoplasias planejados com IMRT, contrastados com planejamentos com VMAT, em estudo prévio na instituição. A técnica Lattice de Radioterapia Espacialmente Fracionada foi utilizada na fração inicial, com prescrição de 5 Gy no volume alvo e 14 Gy nas esferas dispostas dentro do GTV, seguida de quatro frações adicionais de 5 Gy homogêneos no alvo. O estudo revelou maior dificuldade na conformação da dose prescrita nos picos, evidenciada pela variação no índice de conformidade, com média de 1,85 ± 0,27 para IMRT e 1,19 ± 0,24 para VMAT. A análise apontou uma discrepância de +4,1% na dose média nos picos e uma razão de 3,7 nos MUs. Apesar de ambos atenderem aos critérios de qualidade na avaliação gama, o tempo de feixe ativo no IMRT foi 3,6 vezes maior que no VMAT. A análise das doses em OARs sugere equivalência entre as abordagens. Este estudo destaca a potencial equivalência entre SFRT com a técnica Lattice utilizando IMRT versus VMAT, conclui-se que ambas têm particularidades, sendo a escolha baseada em necessidades clínicas, eficiência do tratamento e disponibilidade de tecnologia. O aumento de MU e tempo de feixe ativo foram as principais limitações do IMRT, mas sua eficácia na preservação de órgãos críticos foi destacada, reforçando a segurança e personalização do tratamento radioterápico com IMRT na aplicação da técnica Lattice. | pt_BR |
| dc.identifier.uri | https://ninho.inca.gov.br/jspui/handle/123456789/15715 | |
| dc.language.iso | por | pt_BR |
| dc.subject | Radioterapia de Intensidad Modulada | pt_BR |
| dc.subject | Radiotherapy, Intensity-Modulated | pt_BR |
| dc.subject | Radioterapia de Intensidade Modulada | pt_BR |
| dc.subject | Lattice | pt_BR |
| dc.terms.abstract | The comparative study included ten neoplasia cases planned with IMRT, contrasted with VMAT plans previously studied in the institution. The Lattice Spatially Fractionated Radiation Therapy technique was applied in the initial fraction, prescribing 5 Gy to the target volume and 14 Gy to spheres within the GTV, followed by four additional fractions of 5 Gy homogeneous in the target. The study revealed greater difficulty in conforming the prescribed dose to peaks, evidenced by the conformity index variation, averaging 1.85 ± 0.27 for IMRT and 1.19 ± 0.24 for VMAT. The analysis indicated a +4.1% discrepancy in the average dose at peaks and a 3.7 ratio in MUs. Although both met quality criteria in gamma evaluation, IMRT's beam-on time was 3.6 times longer than VMAT. The analysis of OAR doses suggests comparability between approaches. This study emphasizes the potential equivalence between SFRT with the Lattice technique using IMRT versus VMAT. It concludes that both have peculiarities, with the choice based on clinical needs, treatment efficiency, and technology availability. The increase in MUs and beam-on time were IMRT's main limitations, but its efficacy in preserving critical organs was highlighted, reinforcing the safety and personalization of radiotherapeutic treatment with IMRT in the application of the Lattice technique. | pt_BR |
| dc.title | Radioterapia lattice: um estudo comparativo de viabilidade da técnica IMRT com a VMAT | pt_BR |
| dc.title.alternative | Lattice radiotherapy: a comparative feasibility study of IMRT with VMAT | pt_BR |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Radioterapia Lattice_ Um Estudo Comparativo de Viabilidade entre IMRT e VMAT.pdf
- Size:
- 756.4 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.6 KB
- Format:
- Item-specific license agreed upon to submission
- Description: