Please use this identifier to cite or link to this item:
https://ninho.inca.gov.br/jspui/handle/123456789/10793
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Saint’Yves, Thalis Leon de Ávila | - |
dc.contributor.author | Bueno, Ryenne Banolas | - |
dc.date.accessioned | 2022-09-23T14:23:22Z | - |
dc.date.available | 2022-09-23T14:23:22Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | BUENO, Ryenne Bañolas. Caracterização de um sistema dosimétrico de luminescência opticamente estimulada (OSL) para tomografia computadorizada. 2016. Trabalho de Conclusão de Curso (Residência em Física Média- Ênfase em Imagem) - Instituto Nacional de Câncer, Rio de Janeiro, 2016. | pt_BR |
dc.identifier.uri | http://sr-vmlxaph03:8080/jspui/handle/123456789/10793 | - |
dc.description | 48 p.: il. color. | pt_BR |
dc.description.abstract | Os detectores por luminescência opticamente estimulada (OSL) vêm sendo testados como instrumento alternativo em dosimetria, devido as suas características e vantagens como, alta sensibilidade, facilidade na leitura e repetição da leitura mais de uma vez. Os detectores utilizados no trabalho foram nanoDotTM de óxido de alumínio dopado com carbono (Al2O3:C) e a leitora OSL microStar® , ambos fabricados pela empresa norte-americana Landauer Inc., que juntos fazem parte do sistema InLight® . Este trabalho caracterizou os dosímetros OSL para o equipamento de tomografia computadorizada (TC). Os parâmetros intrínsecos dos detectores e da geometria da irradiação foram testados e avaliados. Os parâmetros da leitora microStar® , CAL, LED e DKR, se mostraram estáveis e dentro dos parâmetros estabelecidos pelo fabricante. Os dosímetros OSL se apresentaram reprodutíveis para um ciclo de até dez medidas consecutivas depois de irradiados e o desvanecimento do sinal não foi significativo. Com a variação da dose o sinal OSL se mostrou linear não apresentando dependência. Porém, os dosímetros OSL apresentaram dependência energética e com relação ao ângulo de radiação incidente necessitando de fatores de correções para o cálculo da dose entregue no detector. Os resultados deste trabalho mostraram a possibilidade da utilização de detectores OSL como um instrumento adicional em dosimetria de equipamentos de TC. | pt_BR |
dc.description.abstract | The detectors by optically stimulated luminescence (OSL) have been tested as an alternative instrument in dosimetry, due to their characteristics and advantages as high sensitivity, spatial resolution, ease of reading and repeat more than once reading. The detectors used at work were nanoDotTM aluminum oxide doped with carbon (Al2O3:C) and reader OSL microStar® , both manufactured by the American company Landauer Inc., which together form part of InLight® system. This study characterized the OSL dosimeters for computed tomography equipment (CT). The intrinsic parameters of the detectors and geometry of irradiation were tested and evaluated.The parameters of microStar® reader, CAL, LED and DKR, were stable within the parameters established by the manufacturer. The OSL dosimeters presented reproducible for a cycle of up to ten consecutive measurements after irradiated. With the variation of the dose OSL signal having a linear showed no dependence. However, the OSL dosimeters showed energy dependence and in relation to the incident radiation angle requiring correction factors for the calculation of the dose delivered to the detector. The results of this study showed the possibility of using OSL detectors as an additional tool in CT dosimetry equipment | - |
dc.language.iso | other | pt_BR |
dc.subject | Tomografia Computadorizada por Raios X | pt_BR |
dc.subject | Tomography, X-Ray Computed | pt_BR |
dc.subject | Tomografía Computarizada por Rayos X | pt_BR |
dc.subject | Dosimetria | pt_BR |
dc.subject | Dosimetry | pt_BR |
dc.subject | Dosimetría | pt_BR |
dc.title | Caracterização de um sistema dosimétrico de luminescência opticamente estimulada (OSL) para tomografia computadorizada | pt_BR |
dc.Type | Bachelor Thesis | pt_BR |
Appears in Collections: | Trabalhos de Conclusão de Curso da Área de Ensino Multiprofissional |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
TCC Ryenne.pdf | 841.97 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.