Please use this identifier to cite or link to this item: https://ninho.inca.gov.br/jspui/handle/123456789/11347
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorErlich, Felipe-
dc.contributor.authorRamos, Bibiana Ferreira Gouvea-
dc.date.accessioned2022-11-16T16:27:01Z-
dc.date.available2022-11-16T16:27:01Z-
dc.date.issued2019-
dc.identifier.citationRAMOS, Bibiana Ferreira Gouvea. Avaliação dosimétrica de heterogeneidade em planejamentos radioterápicos de pacientes com tumores de orofaringe e presença de material metálico odontológico. 2019. Trabalho de Conclusão de Curso (Residência Médica em Radioterapia) - Instituto Nacional de Câncer, Rio de Janeiro, 2019.pt_BR
dc.identifier.urihttp://sr-vmlxaph03:8080/jspui/handle/123456789/11347-
dc.description21 p.: il. color.pt_BR
dc.description.abstractIntrodução: O organismo humano é formado por uma variedade de tecidos e cavidades que do ponto de vista radiológico apresentam diferentes propriedades físicas. Este fato é importante em termos de perspectivas dosimétricas na radioterapia. A distribuição de dose é afetada por essa heterogeneidade, podendo ocorrer subdosagem de volumes ou distribuições incorretas de curvas de isodoses. Materiais metálicos possuem densidade ainda maior que qualquer tecido humano, podendo alterar a distribuição de dose do tratamento estabelecido. Alguns centros de radioterapia não utilizam as correções de densidade de tecidos paciente-específico, os quais calculam a distribuição de dose assumindo que o paciente é composto inteiramente por água. Objetivo: comparar, em pacientes com câncer de orofaringe com presença de material metálico em cavidade oral, as diferenças entre os planejamentos que consideram a heterogeneidade com aqueles que a ignoram. Método: selecionou-se 6 planejamentos de tratamento em pacientes com câncer de orofaringe com presença de estrutura metálica em cavidade oral, nos quais não foram considerados a correção de heterogeneidade. Planejamentos com técnica 3D-CRT ou IMRT com energia de fótons de 6 MV eram elegíveis. Foi aplicado o fator de heterogeneidade levando em consideração a mandíbula e estruturas metálicas para analisar as diferenças em curvas de isodose, cobertura do alvo e localização de pontos quentes. Foram atribuídos valores de 3000 HU para estruturas metálicas, 1500 HU para mandíbula e 50 HU para demais estruturas. Resultados: em 100% dos tratamentos foram observados diferença na localização dos pontos quentes. Em 2 casos houve aumento do número de cortes tomográficos com presença pontos quentes em mandíbula. Em 3 casos houve perda na cobertura do CTV, não atingindo o valor de 100% da prescrição, e em 1 caso houve perda de dose em 97% do volume do PTV. Conclusão: Aplicando-se a correção de heterogeneidade, foram encontradas diferenças nas distribuições de doses nos planejamentos avaliados. Houve subdosagem em volumes clínicos (GTV e CTV) e deslocamento de pontos quentes para órgãos de risco com maior densidade. O presente estudo propõe a importância da correção de heterogeneidade na análise de planejamentos em radioterapia.pt_BR
dc.language.isoporpt_BR
dc.subjectNeoplasias Orofaríngeaspt_BR
dc.subjectOropharyngeal Neoplasmspt_BR
dc.subjectRadioterapiapt_BR
dc.subjectRadiotherapypt_BR
dc.titleAvaliação dosimétrica de heterogeneidade em planejamentos radioterápicos de pacientes com tumores de orofaringe e presença de material metálico odontológicopt_BR
dc.TypeTCCpt_BR
dc.contributor.advisorcoFernandez, Cláudia Regina Scaramello Hadlich Willis-
dc.degree.grantorINCApt_BR
dc.degree.departmentCOENSpt_BR
dc.degree.programRadioterapiapt_BR
dc.degree.localRio de Janeiropt_BR
dc.terms.abstractIntroduction: The human organism consists of a variety of tissues and cavities that from the radiological point of view present different physical properties. It is a remarkable fact concerning the dosimetric perspectives in radiotherapy since heterogeneity may affect dose distribution. Since metal materials are denser than any human tissue, the presence of these materials in treatment areas may lead to underdosing or incorrect distributions of isodose curves. Some treatment centers do not apply density corrections to patient-specific tissues. Those centers calculate the dose distribution under the assumption that the patient is composed of a homogeneous material whose density is that of the water. This study investigates the effects of not considering heterogeneity in radiation therapy plans for patients with oropharyngeal tumors and the presence of metallic dental material. Objective: The objective of this study was to analyze the differences between the plans that consider heterogeneity with those that ignore it in the treatment of patients with oropharyngeal cancer in the presence of metallic material in the oral cavity. Methods: The data for this study came from 6 treatment plans of patients with oropharyngeal cancer in the presence of metallic material in the oral cavity. Those treatments disregarded the heterogeneity correction. All measurements in this study were based on the use of 6 MV photon beams produced using 3D-CRT or IMRT techniques. This study analyzed those treatments with the application of the heterogeneity factor, taking into consideration the jaw and metallic structures. This research examined the differences between the isodose curves, target covering and hot spots. Values of 3000 HU, 1500 HU, and 50 HU were set to the metallic structures, jaws, and remaining structures, respectively. Results: There were differences in the location of hot spots observed in 100% of treatments. The increase of tomographic sections with the presence of hot spots in the mandible occurred in 2 cases. There was a loss of CTV coverage, not reaching 100% of the dose prescription, in 3 cases, and in 1 case there was dose loss in 97% of the PTV volume. Conclusion: This study found differences between the dose distributions of the investigated plans concerning the application of the heterogeneity correction. There was underdosing in clinical volumes (GTV and CTV) and displacement of hot spots to higher density organs at risk. This study concludes on the importance of the heterogeneity correction along treatment plans and proposes to apply such correction to cases of patients with oropharyngeal tumors and metallic dental material.pt_BR
Appears in Collections:Trabalhos de Conclusão de Curso da Área de Ensino Médico

Files in This Item:
File Description SizeFormat 
BIBIANA FERREIRA GOUVEA RAMOS.pdf1.06 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.