Please use this identifier to cite or link to this item:
https://ninho.inca.gov.br/jspui/handle/123456789/12445
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Garcia, Paulo Lazaro | - |
dc.contributor.author | Santos, Maíra Ribeiro dos | - |
dc.contributor.author | Batista, Delano Valdivino Santos | - |
dc.contributor.author | Trindade, Cássia | - |
dc.contributor.author | Martins, Laís Paulino | - |
dc.contributor.author | Silva, Leonardo Peres da | - |
dc.date.accessioned | 2023-01-24T18:38:52Z | - |
dc.date.available | 2023-01-24T18:38:52Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 1984-9001 | - |
dc.identifier.uri | https://ninho.inca.gov.br/jspui/handle/123456789/12445 | - |
dc.description.abstract | O tratamento com radioterapia externa de linfoma de Hodgkin na região acima do diafragma, requer um campo de radiação grande e com proteções de laringe, cabeça de úmero e pulmões. Esse formato do campo e sua grande extensão, que abrange diferentes DAPs, dificulta a entrega de dose homogênea. Técnicas como field-in-field e compensação eletrônica podem ser utilizadas para homogeneizar a dose e compensar a obliquidade do tecido. Três tipos de planejamento foram realizados para um paciente diagnosticado com Linfoma de Hodgkin do tipo esclerose nodular: um plano com dois campos, AP-PA (Plano AP), outro com quatro campos field-in-field (Plano FF), e o terceiro com dois campos e compensação eletrônica (Plano CE). Foram observados melhores gradiente, cobertura do PTV e distribuição de dose para o Plano CE, além da vantagem de este não necessitar da confecção dos blocos de proteção, enquanto os Planos AP e FF apresentam dosimetria mais simples e menos UM. Em relação à uniformidade da entrega da dose, o Plano AP apresentou áreas quentes na região do pescoço, o Plano FF apresentou áreas quentes na região dos ombros, e o Plano CE se mostrou mais uniforme sem áreas quentes. A compensação eletrônica é uma ferramenta útil para campos extensos e modelados como o campo de manto, mas deve-se levar em consideração a alta UM e a dosimetria mais complexa | pt_BR |
dc.publisher | Revista Brasileira de Física Médica.2012:6(3):145-8 | pt_BR |
dc.subject | Radioterapia | pt_BR |
dc.subject | Radiotherapy | pt_BR |
dc.subject | Políticas de eSaúde | pt_BR |
dc.subject | eHealth Policies | pt_BR |
dc.subject | Compensação e Reparação | pt_BR |
dc.subject | Compensation and Redress | pt_BR |
dc.subject | Eletrônica | pt_BR |
dc.subject | Electronics | pt_BR |
dc.subject | manto | pt_BR |
dc.title | Comparação entre técnica 3D convencional, field-in-field e compensação eletrônica para planejamento de manto | pt_BR |
dc.title.alternative | Comparison between 3D conventional techniques, field-in-field and electronic tissue compensation for mantle fields planning | pt_BR |
dc.Type | Article | pt_BR |
dc.terms.abstract | External radiotherapy treatment for Hodgkin’s lymphoma over diaphragm region requires large radiation fields with protections applied to larynx, humerus head and lungs. The size and shape of the field, which covers different depths, make it difficult to distribute a homogeneous dose. Techniques such as field-in-field and electronic tissue compensation may be used to make dose homogeneous and compensate the obliquity from the tissue. Three types of planning were performed for diagnose of nodular sclerosis Hodgkin’s lymphoma: one plan with two fields, AP-PA (AP plan), another with four fields field-in- field (FF plan), and a third one with two fields and electronic tissue compensation (ETC plan). Results showed better gradient, cover of PTV and dose distribution for the ETC plan, besides the advantage from this technique of doesn’t require protection blocks. In the meanwhile, AP and FF plans require simpler dosimetry and fewer MU. Related to the uniformity of dose distribution, AP plan showed hot areas in the neck region, FF plan showed hot areas in the shoulder region and ETC plan showed most uniform distribution without hot areas. The electronic tissue compensation is a useful tool for large and shaped fields as the mantle field, however higher MU and complex dosimetry should be taken in account. | pt_BR |
Appears in Collections: | Artigos de Periódicos da área de Detecção Precoce |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Comparação entre técnica 3D convencional, field-in-field e compensação eletrônica para planejamento de manto.PDF | 1.85 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.