Please use this identifier to cite or link to this item:
https://ninho.inca.gov.br/jspui/handle/123456789/12450
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Garcia, Paulo Lazaro | - |
dc.contributor.author | Silva, Leonardo Peres da | - |
dc.contributor.author | Alves, Victor Gabriel Leandro | - |
dc.contributor.author | Santos, Maíra Ribeiro dos | - |
dc.contributor.author | Trindade, Cássia | - |
dc.contributor.author | Martins, Laís Paulino | - |
dc.contributor.author | Batista, Delano Valdivino Santos | - |
dc.date.accessioned | 2023-01-24T19:11:22Z | - |
dc.date.available | 2023-01-24T19:11:22Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 1984-9001 | - |
dc.identifier.uri | https://ninho.inca.gov.br/jspui/handle/123456789/12450 | - |
dc.description.abstract | Este trabalho apresentou o controle de qualidade para RapidArc utilizando simulador de corpo humano Alderson e filme radiocrômico como uma alternativa de sistema de aprovação final do planejamento de tratamento para tumores de crânio. Deste modo, foram comparadas as distribuições de dose fornecidas pelo sistema de planejamento com aquelas medidas pelo filme radiocrômico. A análise do índice gama (Γ índex) para verificar a aceitabilidade dos cálculos de distribuição de dose, apresentaram 95% de pontos de aprovação, sendo a maioria dos pontos de não conformidade em regiões próximas das bordas do PTV. Podemos tentar justificar tais pontos de não conformidade aos aspectos de transmissão das lâminas devido à região das bordas apresentarem perdas significativas se comparados às áreas centrais. O Programa MATLAB também se mostrou uma ferramenta eficiente para tais medidas e pode ser usado em programas de controle de qualidade. | pt_BR |
dc.publisher | Revista Brasileira de Física Médica.2012;6(3):141-4 | pt_BR |
dc.subject | Controle de Qualidade | pt_BR |
dc.subject | Quality Control | pt_BR |
dc.subject | Filmes Cinematográficos | pt_BR |
dc.subject | Motion Pictures | pt_BR |
dc.subject | Radioterapia | pt_BR |
dc.subject | Radiotherapy | pt_BR |
dc.subject | simulador antropomórfico | pt_BR |
dc.subject | RapidArc | pt_BR |
dc.title | Controle de qualidade em RapidArc com simulador de corpo humano antropomórfico Alderson utilizando filme radiocrômico em comparação ao MATLAB | pt_BR |
dc.title.alternative | Quality assurance in RapidArc with Alderson anthropomorphic phantom using radiochromic film in comparison to MATLAB | pt_BR |
dc.Type | Article | pt_BR |
dc.terms.abstract | This paper presented the quality control for RapidArc using an Alderson human body phantom and radiocromic film as an alternative system to approve the treatment plan for brain tumor. Thus, it was comprised the dose distributions provided by the treatment planning system with those measured by the film radiocromic. The gamma index (Γ) analysis, to verify the acceptability of the dose distribution, was 95% of approved points, with the mostly non-compliance points in regions near the PTV’s edges. These non-compliance points may be associated to transmission blades aspects, because the regions near the edges present significant losses compared to the central areas. Also, MATLAB has proved an effective tool for that measurements and it can be used in quality assurance programs. | pt_BR |
Appears in Collections: | Artigos de Periódicos da área de Detecção Precoce |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Controle de qualidade em RapidArc com simulador de corpo humano antropomórfico Alderson utilizando filme radiocrômico em comparação ao MATLA.PDF | 2.4 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.