dc.description.abstract | Novas tecnologias vêm sendo desenvolvidas para a melhoria da verificação da garantia de qualidade dos planejamentos com feixes modulados. Uma alternativa para os altos custos de equipamentos de dosimetria foi desenvolver um fantoma 3D, utilizando TLDs e filme radiocrômico, projetado pelo Programa de Qualidade em Radioterapia (PQRT) do INCA. Os cálculos foram feitos usando o algoritmo AAA, com correção de heterogeneidade, inserindo assim, diversas heterogeneidades no volume deste fantoma. Realizaram-se cinco irradiações correspondente aos planejamentos realizados com RapidArcTM, uma vez que o fantoma foi tomografado para otimização. A proposta do trabalho é a verificação 3D da distribuição de dose gerada no fantoma heterogêneo. O desvio médio encontrado no volume alvo planejado foi menor que ±5%. Já para as outras heterogeneidades a dispersão dos resultados ficou mais elevada, o desvio pontual máximo obtido, por exemplo, na heterogeneidade correspondente à bexiga foi de 7,41%. O desvio padrão máximo encontrado para dois casos foi em torno de 9% para a heterogeneidade do alvo e de 11% entre as demais heterogeneidades. O fantoma pode se tornar um equipamento interessante para verificação de planejamentos com RapidArcTM, porém são necessárias maiores estatísticas para se obter melhores resultados para as análises das distribuições de dose. | pt_BR |
dc.publisher | Revista Brasileira de Física Médica.2013;7(3):123-8 | pt_BR |
dc.subject | Controle de Qualidade | pt_BR |
dc.subject | Quality Control | pt_BR |
dc.subject | Radioterapia | pt_BR |
dc.subject | Radiotherapy | pt_BR |
dc.subject | Planejamento da Radioterapia Assistida por Computador | pt_BR |
dc.subject | Radiotherapy Planning Computer-Assisted | pt_BR |
dc.subject | Radioterapia Conformacional | pt_BR |
dc.subject | Radiotherapy Conformal | pt_BR |
dc.title | Verificação de planejamentos de RapidArcTM com algoritmo AAA usando um fantoma heterogêneo 3D | pt_BR |
dc.title.alternative | Verification of RapidArcTM planning with AAA algorithm using an inhomogeneous 3D phantom | pt_BR |
dc.Type | Article | pt_BR |
dc.terms.abstract | New technologies have been developed to improve the quality assurance of the plannings with modulated beams. One way to deal with the high costs of the dosimetry equipaments was to develop a 3D phantom, using TLDs and radiocromic film, designed by the Radiotherapy Quality Program of INCA. The calculus was done using the AAA algorithm with heterogeneity correction, making the phantom rather heterogeneous. Five measurements related to the RapidArcTM planning were taken, once there was the phantom CT for optimization. The purpose of this work is a 3D verification of the dose distribution in the heterogeneous phantom. The mean deviation in planning target volumes was lower than ±5%. On the other side, the results dispersion for the others heterogeneities was higher, the maximum mean deviation obtained, for example, for the heterogeneity related to the bladder, was 7.41%. The maximum standard deviation found for both cases was around 9% for the target heterogeneity and 11% for the other heterogeneities. The phantom might be an interesting tool in order to verify the RapidArcTM planning, however, more statistical data is necessary as to achieve better results for the analysis of dose distribution. | pt_BR |