Please use this identifier to cite or link to this item: https://ninho.inca.gov.br/jspui/handle/123456789/14280
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAugusto, Fernando Mecca-
dc.contributor.authorAndrade, Marcos Ely Almeida-
dc.contributor.authorJakubiak, Rosangela Requi-
dc.contributor.authorKhoury, Helen Jamil-
dc.contributor.authorRenha, Simone Kodlulovich-
dc.contributor.authorMiquelin, Charlie Antoni-
dc.contributor.authorNader, Alejandro-
dc.date.accessioned2023-06-22T16:29:51Z-
dc.date.available2023-06-22T16:29:51Z-
dc.date.issued2012-
dc.identifier.citationAUGUSTO, Fernando Mecca et al. Volume computed tomography air kerma index and image quality evaluation in Brazil. Radiation Protection Dosimetry, v. 148, n. 4, p. 452–456, 2012.-
dc.identifier.issn1742-3406-
dc.identifier.urihttps://ninho.inca.gov.br/jspui/handle/123456789/14280-
dc.descriptionp. 452–456.: il. p&b.-
dc.description.abstractThe aim of this study was to evaluate the image quality of 29 computed tomography (CT) scanners in Brazil and to perform estimations of patient dose and image quality of common CT examinations at these equipment. The volume CT air kerma indexes (C(VOL)) were estimated, using normalised weighted air kerma indexes, supplied by the ImPACT group. The image quality tests were performed using the phantom and accreditation protocol from the American College of Radiology (ACR). The C(VOL) values for head scans varied between 8.7 and 108 mGy. The Hi-res chest examinations presented C(VOL) values varying from 0.4 to 32 mGy. For abdominal scans, the estimated C(VOL) values varied between 4.1 and 94 mGy. This wide variation of air kerma between different centres is related to the scanner type and also to the scanning parameters. The results also showed that the image quality did not attend all ACR CT accreditation requirements.pt_BR
dc.publisherRadiation Protection Dosimetrypt_BR
dc.subjectTomografia Computadorizada por Raios Xpt_BR
dc.subjectTomography, X-Ray Computedpt_BR
dc.subjectKermapt_BR
dc.subjectBrazilpt_BR
dc.subjectBrasilpt_BR
dc.titleVolume computed tomography air kerma index and image quality evaluation in Brazilpt_BR
dc.TypeArticlept_BR
Appears in Collections:Artigos de Periódicos da área de Física Médica

Files in This Item:
File Description SizeFormat 
Volume computed tomography air kerma index and image quality evaluation in Brazil.pdf220.89 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.