dc.contributor.author | Burgos, Adam de Freitas | - |
dc.contributor.author | Silva, Leonardo Peres da | - |
dc.contributor.author | Paiva, Eduardo de | - |
dc.date.accessioned | 2024-01-02T17:43:51Z | - |
dc.date.available | 2024-01-02T17:43:51Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | BURGOS, Adam de Freitas; SILVA, Leonardo Peres da; PAIVA, Eduardo de. Realização do teste end-to-end para a caracterização de um simulador em radioterapia estereotática de fígado. Brazilian Journal of Radiation Sciences, v. 6, p. 1-11, 2018. | - |
dc.identifier.issn | 2319-0612 | - |
dc.identifier.uri | https://ninho.inca.gov.br/jspui/handle/123456789/15280 | - |
dc.description | p. 1-11.: il. color. | - |
dc.description.abstract | Atualmente, por conta do seu bom prognóstico, uma das alternativas ao tratamento radioterápico do fígado é a radioterapia estereotática corpórea (SBRT), que entrega altas doses ao volume alvo em poucas frações. No entanto, para que se assegure que o elevado valor de dose entregue ao alvo seja o mesmo que o planejado, um teste de verificação de todo o processo (aquisição de imagens, delineamento, planejamento e a entrega da dose) deve ser realizado. Para isto, o objetivo deste trabalho foi desenvolver um simulador, com densidade de água, que leva em conta a posição relativa do fígado e dos órgãos de risco envolvidos neste tratamento, avaliando a influência da movimentação do alvo, em virtude do processo respiratório, no valor da dose por ele recebida. Também foram avaliados os valores de dose nas posições relativas aos órgãos de risco. | pt_BR |
dc.publisher | Brazilian Journal of Radiation Sciences | pt_BR |
dc.subject | SBRT | pt_BR |
dc.subject | Fígado | pt_BR |
dc.subject | Liver | pt_BR |
dc.subject | Efeito interplay | pt_BR |
dc.subject | Interplay effect | pt_BR |
dc.subject | Dosimetria | pt_BR |
dc.subject | Dosimetry | pt_BR |
dc.title | Realização do teste end-to-end para a caracterização de um simulador em radioterapia estereotática de fígado | pt_BR |
dc.Type | Article | pt_BR |
dc.terms.abstract | Nowadays, one of the alternatives to the radiotherapy treatment of the liver is the stereotactic body radiation therapy (SBRT), which delivers high doses to the target volume in a few fractions. However, in order to ensure that the high dose value delivered to the target is the same as planned, a full process verification known as test end-to-end (image acquisition, design, planning, and dose delivery) should be performed. The aim of this work was to develop a water density simulator that takes into account the relative position of the liver and the risk organs involved in this treatment, evaluating the influence of the movement of the target, due to the respiratory process, in the value of the dose received by the target. The dose values were also evaluated in the positions related to the risk organs. | pt_BR |