Please use this identifier to cite or link to this item: https://ninho.inca.gov.br/jspui/handle/123456789/5139
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFranco, Andrezza Serpa-
dc.contributor.authorBridi, Adriana Carla-
dc.contributor.authorKaram, Monica de Almeida-
dc.contributor.authorMoreira, Ana Paula Amorim-
dc.contributor.authorAndrade, Karla Biancha Silva de-
dc.contributor.authorSilva, Roberto Carlos Lyra da-
dc.date.accessioned2022-02-16T13:18:38Z-
dc.date.available2022-02-16T13:18:38Z-
dc.date.issued2017-
dc.identifier.issn1984-0446-
dc.identifier.urihttp://sr-vmlxaph03:8080/jspui/handle/123456789/5139-
dc.description2017 nov-dez;70(6):1273-9-
dc.description.abstractObjetivo: Caracterizar os alarmes sonoros disparados pelo balão intra-aórtico (BIA) durante a terapia de contrapulsação aórtica; medir o tempo estímulo-resposta da equipe a esses e discutir as implicações do alargamento desse tempo para a segurança do paciente na perspectiva da fadiga de alarmes. Método: Trata-se de um estudo descritivo observacional, com abordagem quantiqualitativa, do tipo estudo de caso, realizado em uma Unidade de Terapia Cardiointensiva Cirúrgica. Resultados: O alarme sonoro mais disparado pelo BIA foi o de pressão diastólica aumentada-diminuída, de alta prioridade. O tempo estímulo-resposta foi em média de 33,9 segundos. Conclusão: O gerenciamento dos alarmes desses equipamentos torna-se imprescindível para minimizar a ocorrência do fenômeno fadiga de alarmes e na oferta de uma assistência mais segura ao paciente dependente dessa tecnologia.-
dc.publisherRev Bras Enferm [Internet]pt_BR
dc.subjectCuidados Críticospt_BR
dc.subjectCritical Carept_BR
dc.subjectMonitoramentopt_BR
dc.subjectMonitoringpt_BR
dc.subjectAlarmes Clínicospt_BR
dc.subjectClinical Alarmspt_BR
dc.subjectNear Misspt_BR
dc.subjectNear Miss Healthcarept_BR
dc.subjectSegurança do Pacientept_BR
dc.subjectPatient Safetypt_BR
dc.titleTempo estímulo-resposta aos alarmes do balão intraórtico: práticas para cuidado seguropt_BR
dc.title.alternativeStimulus-response time to alarms of the intra-aortic balloon pump: safe care practicespt_BR
dc.title.alternativeEl tempo estíulo-respuesta de las alarmas del balón de contrapulsación intraaórtico: prácticas para el cuidado seguropt_BR
dc.TypeArticlept_BR
dc.description.abstractenObjective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP) during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.-
dc.description.abstractesObjetivo: Caracterizar las alarmas sonoras disparadas por el balón de contrapulsación intraaórtico (BCIA) durante la terapia de contrapulsación aórtica; calcular el tiempo estímulo-respuesta del dispositivo y discutir las implicaciones al extenderse el tiempo para la seguridad del paciente cuando presente fatiga por las alarmas. Método: Estudio descriptivo observacional, con enfoques cuantitativo y cualitativo, de tipo estudio de caso, llevado a cabo en una Unidad de Cuidado Cardiontensivo Quirúrgico. Resultados: La alarma sonora más disparada por el BCIA fue la de la diástole aumentada y disminuida, de alta necesidad. El promedio del tiempo estímulo-respuesta fue de 33,9 segundos. Conclusión: La gestión de las alarmas de este dispositivo se hace imprescindible para minimizar su fatiga a los pacientes que lo utilizan y para ofrecerles un cuidado más seguro.-
Appears in Collections:Artigos de Periódicos da área de Enfermagem

Files in This Item:
File Description SizeFormat 
Stimulus response time to alarms of the intra aortic balloon pump safe care practices.pdf171.15 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.