Please use this identifier to cite or link to this item:
https://ninho.inca.gov.br/jspui/handle/123456789/5139
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Franco, Andrezza Serpa | - |
dc.contributor.author | Bridi, Adriana Carla | - |
dc.contributor.author | Karam, Monica de Almeida | - |
dc.contributor.author | Moreira, Ana Paula Amorim | - |
dc.contributor.author | Andrade, Karla Biancha Silva de | - |
dc.contributor.author | Silva, Roberto Carlos Lyra da | - |
dc.date.accessioned | 2022-02-16T13:18:38Z | - |
dc.date.available | 2022-02-16T13:18:38Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 1984-0446 | - |
dc.identifier.uri | http://sr-vmlxaph03:8080/jspui/handle/123456789/5139 | - |
dc.description | 2017 nov-dez;70(6):1273-9 | - |
dc.description.abstract | Objetivo: Caracterizar os alarmes sonoros disparados pelo balão intra-aórtico (BIA) durante a terapia de contrapulsação aórtica; medir o tempo estímulo-resposta da equipe a esses e discutir as implicações do alargamento desse tempo para a segurança do paciente na perspectiva da fadiga de alarmes. Método: Trata-se de um estudo descritivo observacional, com abordagem quantiqualitativa, do tipo estudo de caso, realizado em uma Unidade de Terapia Cardiointensiva Cirúrgica. Resultados: O alarme sonoro mais disparado pelo BIA foi o de pressão diastólica aumentada-diminuída, de alta prioridade. O tempo estímulo-resposta foi em média de 33,9 segundos. Conclusão: O gerenciamento dos alarmes desses equipamentos torna-se imprescindível para minimizar a ocorrência do fenômeno fadiga de alarmes e na oferta de uma assistência mais segura ao paciente dependente dessa tecnologia. | - |
dc.publisher | Rev Bras Enferm [Internet] | pt_BR |
dc.subject | Cuidados Críticos | pt_BR |
dc.subject | Critical Care | pt_BR |
dc.subject | Monitoramento | pt_BR |
dc.subject | Monitoring | pt_BR |
dc.subject | Alarmes Clínicos | pt_BR |
dc.subject | Clinical Alarms | pt_BR |
dc.subject | Near Miss | pt_BR |
dc.subject | Near Miss Healthcare | pt_BR |
dc.subject | Segurança do Paciente | pt_BR |
dc.subject | Patient Safety | pt_BR |
dc.title | Tempo estímulo-resposta aos alarmes do balão intraórtico: práticas para cuidado seguro | pt_BR |
dc.title.alternative | Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices | pt_BR |
dc.title.alternative | El tempo estíulo-respuesta de las alarmas del balón de contrapulsación intraaórtico: prácticas para el cuidado seguro | pt_BR |
dc.Type | Article | pt_BR |
dc.description.abstracten | Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP) during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology. | - |
dc.description.abstractes | Objetivo: Caracterizar las alarmas sonoras disparadas por el balón de contrapulsación intraaórtico (BCIA) durante la terapia de contrapulsación aórtica; calcular el tiempo estímulo-respuesta del dispositivo y discutir las implicaciones al extenderse el tiempo para la seguridad del paciente cuando presente fatiga por las alarmas. Método: Estudio descriptivo observacional, con enfoques cuantitativo y cualitativo, de tipo estudio de caso, llevado a cabo en una Unidad de Cuidado Cardiontensivo Quirúrgico. Resultados: La alarma sonora más disparada por el BCIA fue la de la diástole aumentada y disminuida, de alta necesidad. El promedio del tiempo estímulo-respuesta fue de 33,9 segundos. Conclusión: La gestión de las alarmas de este dispositivo se hace imprescindible para minimizar su fatiga a los pacientes que lo utilizan y para ofrecerles un cuidado más seguro. | - |
Appears in Collections: | Artigos de Periódicos da área de Enfermagem |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Stimulus response time to alarms of the intra aortic balloon pump safe care practices.pdf | 171.15 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.