Please use this identifier to cite or link to this item: https://ninho.inca.gov.br/jspui/handle/123456789/6859
Full metadata record
DC FieldValueLanguage
dc.contributor.authorReis, Fernanda Faria-
dc.contributor.authorSilva, Lucelia dos Santos-
dc.contributor.authorSptiz, Viviane de Moraes-
dc.contributor.authorSilva, Monyque Evelyn dos Santos-
dc.contributor.authorOliveira, Aretha Pereira de-
dc.contributor.authorLima, Dalmo Valério Machado de-
dc.date.accessioned2022-05-09T17:34:31Z-
dc.date.available2022-05-09T17:34:31Z-
dc.date.issued2021-
dc.identifier.citationREIS, Fernanda Faria et al. Padrão oxihemodinâmico não-invasivo durante o banho no leito de pacientes com infarto agudo do miocárdio: Ensaio clínico. Research, Society and Development, v. 10, n. 9, p. 1-11, 2021.-
dc.identifier.issn2525-3409-
dc.identifier.urihttp://sr-vmlxaph03:8080/jspui/handle/123456789/6859-
dc.descriptionp. 1-11.: il. p&b.-
dc.description.abstractObjetivo: Analisar o impacto oxihemodinâmico do banho no leito sem controle da temperatura da água realizado em até 20 minutos em pacientes com infarto agudo do miocárdio. Método: Ensaio clínico não controlado realizado de junho de 2015 a março de 2016, com 23 pacientes infartados na unidade coronariana de um hospital privado em Niterói. Foram registradas variáveis de fluxo sanguíneo, contratilidade cardíaca e oximétricas por um aparelho de bioimpedância cardiográfica antes, durante e após o banho no leito. Foram realizados análise de variância, regressão linear múltipla, teste de Friedman e teste t-student, com nível de significância de 5% (Parecer CEP nº 1285852). Resultados: Houve pouca variação da frequência cardíaca e da pressão arterial nos três momentos. O índice cardíaco e volume sistólico apresentaram variações significativas, sem provocar instabilidade clínica. Conclusão: o banho no leito sem controle da temperatura da água não repercutiu significativamente sobre variáveis de fluxo sanguíneo.-
dc.publisherResearch, Society and Developmentpt_BR
dc.subjectBanhospt_BR
dc.subjectBathspt_BR
dc.subjectBañospt_BR
dc.subjectInfarto do Miocárdiopt_BR
dc.subjectMyocardial Infarctionpt_BR
dc.subjectInfarto del Miocardiopt_BR
dc.subjectHemodinâmicapt_BR
dc.subjectHemodynamicspt_BR
dc.subjectHemodinámicapt_BR
dc.titlePadrão oxihemodinâmico não-invasivo durante o banho no leito de pacientes com infarto agudo do miocárdio: Ensaio clínicopt_BR
dc.title.alternativeNon-invasive oxyhemodynamic pattern during bed bath of patients with acute myocardial infarction: Clinical trialpt_BR
dc.title.alternativeEstándar oxihemodinámico no invasivo durante el baño en lecho de los pacientes con infarto agudo de miocardio: Ensayo clínicopt_BR
dc.TypeArticlept_BR
dc.description.abstractenObjective: To analyze the oxyhemodynamic impact of a bed bath without water temperature control performed within 20 minutes in patients with acute myocardial infarction. Method: Uncontrolled clinical trial conducted from June 2015 to March 2016, with 23 infarcted patients in the coronary care unit of a private hospital in Niterói. Blood flow, cardiac contractility and oximetry variables were recorded by a cardiographic bioimpedance device before, during and after the bed bath. Analysis of variance, multiple linear regression, Friedman test and t-student test were performed, with a significance level of 5% and a 95% confidence interval. Results: There was minor variation in heart rate and blood pressure in the three moments. Cardiac index and stroke volume showed significant variations, without causing clinical instability. Conclusion: the bed bath without water temperature control did not significantly affect blood flow variables.-
dc.description.abstractesObjetivo: Analizar el impacto oxihemodinámico del baño en el lecho sin control de la temperatura del agua realizado en 20 minutos en pacientes con infarto del miocardio. Método: Ensayo clínico no controlado realizado entre junio de 2015 y marzo de 2016, con 23 pacientes con infarto en la unidad coronaria de un hospital privado de Niterói. Las variables de flujo sanguíneo, contractilidad cardíaca y oximetría se registraron mediante un dispositivo de bioimpedancia cardiográfica antes, durante y después del baño en el lecho. Se realizaron análisis de varianza, regresión lineal múltiple, prueba de Friedman y prueba t-student, con un nivel de significancia del 5% y un intervalo de confianza del 95%. Resultados: Hubo poca variación en la frecuencia cardíaca y la presión arterial en los tres momentos. El índice cardíaco y el volumen sistólico mostraron variaciones significativas, sin causar inestabilidad clínica. Conclusión: el baño en el lecho sin control de la temperatura del agua no afectó significativamente las variables de flujo sanguíneo.-
Appears in Collections:Artigos de Periódicos da área de Enfermagem



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.