Please use this identifier to cite or link to this item:
https://ninho.inca.gov.br/jspui/handle/123456789/8594
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Silva, Daniela Guimarães Ferreira da | - |
dc.contributor.author | Souza, Ana Lucia Lira Pessoa de | - |
dc.contributor.author | Martins, Thalyta Cássia de Freitas | - |
dc.contributor.author | Pedrosa, Thais Martins | - |
dc.contributor.author | Muzi, Camila Drumond | - |
dc.contributor.author | Guimarães, Raphael Mendonça | - |
dc.date.accessioned | 2022-07-05T10:40:09Z | - |
dc.date.available | 2022-07-05T10:40:09Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 2358-291X | - |
dc.identifier.uri | http://sr-vmlxaph03:8080/jspui/handle/123456789/8594 | - |
dc.description | 2017, Rio de Janeiro, 25 (2): 152-159 | - |
dc.description.abstract | Objetivo: Verificar a estabilidade teste-reteste do instrumento EORTC QLQ FA13 na versão em português do Brasil por meio do processo de equivalência semântica, compreendendo a fase de equivalência de mensuração que abrange os estudos psicométricos. Métodos: O instrumento foi aplicado em 163 pacientes nas enfermarias clínicas e cirúrgicas de um hospital de alta complexidade no tratamento do câncer situado no município do Rio de Janeiro entre março de 2015 e outubro de 2016, através de um questionário aplicado por entrevista individual. Para testar a adequação do processo de aferição, solicitou-se que respondessem novamente o questionário, com intervalo de 7 a 15 dias. Resultados: Dentre aqueles que participaram do teste, 50 (30,67%) aderiram também ao reteste. Houve boa compreensão do instrumento na etapa de teste. As respostas mostraram-se estáveis, e as estimativas de confiabilidade teste-resteste variaram de boa a excelente (kappa = 0,66 a 0,80), seja para os itens, seja para as dimensões da escala. Conclusão: O presente estudo, juntamente com outras etapas prévias de confiabilidade do instrumento, sugere alta estabilidade das informações coletadas, o que torna real sua aplicabilidade na população brasileira visando à melhora da qualidade da assistência dos pacientes oncológicos. | - |
dc.publisher | Cad. Saúde Colet. | pt_BR |
dc.subject | Fadiga | pt_BR |
dc.subject | Fatigue | pt_BR |
dc.subject | Oncologia | pt_BR |
dc.subject | Medical Oncology | pt_BR |
dc.subject | Estudo de Validação | pt_BR |
dc.subject | Validation Study | pt_BR |
dc.subject | Reprodutibilidade dos Testes | pt_BR |
dc.subject | Reproducibility of Results | pt_BR |
dc.subject | Avaliação em Saúde | pt_BR |
dc.subject | Health Evaluation | pt_BR |
dc.title | Confiabilidade teste-reteste do instrumento EORTC QLQ FA13 para avaliação de fadiga em pacientes oncológicos | pt_BR |
dc.title.alternative | Test-retest reliability of EORTC QLQ FA 13 instrument for fatigue assessment in oncological patients | pt_BR |
dc.Type | Article | pt_BR |
dc.description.abstracten | Objective: To verify the test-retest stability of the EORTC QLQ FA 13 instrument in the Brazilian Portuguese version through the semantic equivalence process, including the equivalence phase of measurement that covers psychometric studies. Methods: The instrument was applied in 163 patients undergoing cancer treatment in the clinical and surgical infirmaries of a highly complex hospitallocated in the city of Rio de Janeiro between March 2015 and October 2016 through a questionnaire applied in an individual interview. In order to test the suitability of the measurement process, participants were requested to answer the questionnaire a second time after and interval of 7 to 15 days. Results: Among participantsed, 50 (30.67%) also adhered to retest. There was good understanding of the instrument at the test stage. The responses were stable, and the estimates of test-retest reliability varied from good to excellent (kappa = 0.66 to 0.80), either for items or for scale dimensions. Conclusion: The present study and other previous steps of reliability of the instrument suggest a high stability of the information collected, which makes its applicability in the Brazilian population useful for improving the quality of care of cancer patients. | - |
Appears in Collections: | Artigos de Periódicos da área de Enfermagem |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Confiabilidade teste-reteste do instrumento EORTC QLQ FA13 para avaliação de fadiga em pacientes oncológicos.pdf | 733.35 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.