Please use this identifier to cite or link to this item:
https://ninho.inca.gov.br/jspui/handle/123456789/2140
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Augusto, Fernando Mecca | - |
dc.contributor.author | Carmo, Antonio Santos do | - |
dc.date.accessioned | 2020-11-18T17:50:52Z | - |
dc.date.available | 2020-11-18T17:50:52Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | CARMO, Antonio Santos do. Comparação da qualidade da imagem em sistemas de mamografia computadorizada CR utilizando placas de imagem com diferentes tempos de uso. 2019. Trabalho de Conclusão de Curso (Residência em Física Médica/Ênfase em Imagem) - Instituto Nacional de Câncer, Rio de Janeiro, 2019 | pt_BR |
dc.identifier.uri | http://sr-vmlxaph03:8080/jspui/handle/123456789/2140 | - |
dc.description | 49 p.: il. p&b, color. | - |
dc.description.abstract | O câncer de mama é, atualmente, uma das maiores causas de morte entre as mulheres em todo o mundo, por isso surge à necessidade de um diagnóstico o mais preciso possível. Logo, tem-se também que haja nos serviços de mamografia um controle de qualidade capaz de garantir uma imagem mamográfica de qualidade. No mundo todo, sistemas nacionais de saúde têm implantado programas de rastreamento populacional de câncer de mama baseados em mamografia, pois há cada vez mais se evidencia a preocupação com a qualidade desse tipo de imagem, bem como o uso seguro da radiação visando oferecer a melhor imagem com o menor nível possível de risco para a paciente. Nas técnicas de imagens médicas usadas em radiologia, a energia usada para produzir a imagem deve ser capaz de penetrar os tecidos de modo que ocorra uma interação entre os fótons de raios X e o tecido em análise. Essa interação leva à preocupação com a possibilidade do surgimento de um câncer induzido por essa radiação. Os avanços tecnológicos nas últimas décadas melhoraram muito a qualidade da imagem mamográfica e, consequentemente, a precisão diagnóstica. Por outro lado, também têm surgido novos desafios no Controle de Qualidade em Mamografia. Neste contexto, este trabalho a presenta uma análise comparativa das imagens mamográfica obtidas utilizando-se três grupos de cassetes Agfa MM3.0 usados em um serviço de mamografia. Os cassetes possuem diferentes tempos de uso e a imagens geradas nos testes foram obtidas utilizando-se o Controle Automático de Exposição (AEC) e foram analisadas com o auxílio do COQ, o plugin do soft ImageJ. Os testes empregados aqui visam a análise da Linearidade do Receptor de Imagem, o Ruído, a Função Transferência de Modulação (MTF), a Eficiência Quântica do Detector (DQE), a Razão contraste-ruído em função da espessura de PMMA e a Dose Glandular Média (DGM) medida no serviço. | pt_BR |
dc.description.abstract | The breast cancer is currently one of the leading causes of death among women worldwide, so there is a need for as accurate a diagnosis as possible. Therefore, there is also a need for quality control in mammography services that can guarantee a quality image. Throughout the world, national health systems have implemented population mammography screening programs based on mammography, as there is increasing concern about the quality of this type of image, as well as the safe use of radiation to provide the best image with the lowest possible level of risk to the patient. In medical imaging techniques used in radiology, the energy used to produce the image must be able to penetrate the tissues so that an interaction between the X-ray photons and the tissue under analysis occurs. This interaction leads to concern about the possibility of cancer arising from exposure of the patient to radiation. The technological advances in the last decades have greatly improved the quality of the image produced in mammography exams and, consequently, the diagnostic accuracy. On the other hand, new challenges have arisen in Mammography Quality Control. In this context, this work presents a comparative analysis of the images using three groups of Agfa MM3.0 cassettes used in a mammography service. The cassettes have different times of use and the images generated in the tests were obtained using Automatic Exposure Control (AEC) and analyzed using the COQ, the soft ImageJ plugin. The tests used here are aimed at analyzing the Image Receiver Linearity, Noise, Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE), Signal-to-Noise Ratio as a function of PMMA thickness and Mean Glandular Dose (MGD) measured in the service. | - |
dc.subject | Neoplasias da Mama | pt_BR |
dc.subject | Mamografia | pt_BR |
dc.subject | Breast Neoplasms | - |
dc.subject | Neoplasias de la Mama | - |
dc.subject | Mammography | - |
dc.subject | Mamografía | - |
dc.title | Comparação da qualidade da imagem em sistemas de mamografia computadorizada CR utilizando placas de imagem com diferentes tempos de uso | pt_BR |
dc.Type | Bachelor Thesis | pt_BR |
Appears in Collections: | Trabalhos de Conclusão de Curso da Área de Ensino Multiprofissional |
Files in This Item:
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.